features 3u x 42te x 310mm input : 10 - 20vdc output : 24vdc 600w eff ciency : 77 % typ. air forced input voltage range : 10 - 20vdc nominal : 12 vdc input protection : fuse transient, surges and reverse polarity protected output output : 24vdc 600w 12 x 24v 50w in parallel operation applications test bench. FAB0504009 1/3 rev. 00 line regulation load regulatio n ripple and noise current limit low line to high line ; full load 10 % to full load peak to peak - bandwidth 20mhz according to o/p voltage vout = 95 % of nominal ; automatic restart conditions typ. 2 % 2 % 2 % 150 % of i nominal 5 % 5 % v1 max.
safety : built to meet en60950 emi : built to meet en55022a, conducted. environmental storage temperature : -40c to +85c operating temperature : 0c to +40c ambiant, nominal power isolation input to chassis : 1500 vdc input to output : 1500 vdc output to chassis : >100 mohms at 500 vdc general signals on/off : switch in rear panel. inhibition of the output input ok : 4 leds in front panel output ok : 12 leds in front panel FAB0504009 2/3 rev. 00
mechanicals pin red +vin description input : power connector anderson pp120 serie black -vin input connectors FAB0504009 3/3 rev. 00 pin red +v1 description output : anderson th030 serie red +v1 black -v1 black -v1 output on/off note : pins above must be connected in parrallel externaly to provid 24vdc 600w
|